Educational simulation · Physics-based

A surgery simulator for fracture fixation

Operate on a bone built from a real CT scan. Break it, fix it with the plates, screws, nails, wires and frames used in the operating room, then load it and read what your fixation does, in newtons and millimeters.

A whole femur, built in 3D from an open CT scan and drawn by Osteon
Guided caseStep 3 of 7

Case 1: lag screw and plate

Lag screw

Take the 4.5 mm partially threaded screw and click the hole. Tighten it to about 80% of its stripping torque.

Its thread past the fracture presses it shut.

Your own scan
  • DICOM: files, a folder or a zip
  • NIfTI, NRRD or MetaImage

Box the bone on two pictures of the scan and it becomes a case. Only its voxels are kept.

30guided cases,
each with a debrief
  • Screws and plates13
  • Nails6
  • The hip7
  • Wires and frames4
A femur broken through its trochanters, from an open CT scan (TotalSegmentator, CC BY 4.0), built and drawn by Osteon.

Fixed with the hardware of the operating room

What Osteon is

Practice the operation before the operation.

Osteon is a fracture-fixation skills lab on a laptop. It turns a CT scan into a bone you can cut, drill, plate, screw and nail as often as you like. Because it runs real mechanics, it shows what a plastic bone cannot: how hard a lag screw presses the fracture, how near each screw is to stripping, and how far the fracture moves under load.

For medical students heading for orthopedics, residents who want repetitions, and the faculty who teach them.

Readings from Osteon's guided cases

2,038 N
press the fracture shut, from one lag screw tightened to 3 N·m Case 1
400 N
along the bone, carried with the plate on: the fracture does not move Case 1
1.6 N·m
strips a plain screw in weak bone, before the driver reaches 3 Case 4

As Osteon's notes record them, on the demo femur. Educational simulation.

How it works

Break it, reduce it, fix it, test it.

One bone, built from the scan, and the steps of a real operation in their order.

Oblique, 45° · AO/OTA 32-A2

Break

Draw the fracture across the bone with the saw, or take the one the scan shows.

A faint copy shows where it belongs

Reduce

Bring the fragment back with pointed forceps and hold it with K-wires.

  • Lag screw, 4.5 mm
  • Plate, 4.5 mm, 6 holes
  • Locking screws, 4

Fix

Drill, measure and drive the screws, put on the plate, ream and nail, or tie a wire.

Load400 N
Motionnone
Plate0%
Held · Case 1, along the bone

Test

Load it along the bone, as the hip in walking, in bending or in torsion, and read what moves.

Guided cases

30 cases, from a lag screw to a sliding hip screw.

Each step gives one instruction and its reason, a red ring marks where to work, and the case ends in a debrief with its numbers. There is no score: the numbers are the feedback.

  1. 01

    Choose a case

    Four topics, each with its progress and the case up next.

    • Screws and plates3 of 13
    • Nails1 of 6
    • The hip0 of 7
    • Wires and frames0 of 4

    Up nextCase 4: weak bone

  2. 02

    Follow its steps

    The step opens its tool and turns the view; you do the work.

    Case 1 · Step 2 of 7

    Hole for the lag screw

    With the 3.2 mm bit, click inside the red ring and drill through the far cortex.

    The screw's thread will grip the far fragment.

    Look along the screw
  3. 03

    Load it

    The strip under the view gives the fracture's state live, in numbers colored by what they mean.

    Pressed623 N
    Load400 N
    Motionnone
    Plate16%

    Case 3, a compression plate on the demo femur: the plate at 16% of its yield.

  4. 04

    Read the debrief

    What happened, why, and what to change. Save it as a text file to show a teacher.

    • Lag screw: 2,038 N of compression, not stripped.
    • Plate: two screws in each fragment.
    • 400 N along the bone: no motion; the pressed fracture carries it.
    Save the debrief

The physics

Real mechanics, nothing scripted.

Compression, stripping, plunge and stability come out of the model, so a wrong technique fails for the real reason, and a right one holds.

A physics engine underneath

An open-source medical simulation engine runs the fragments and the hardware under load, and the contact between the broken faces.

Every number has a source

Bone strength, thread hold, the steel's limits: each constant names the paper or guide it comes from, or is marked as assumed.

Mistakes cost what they cost

Plunge past the far cortex, strip a screw, lose compression, stop a thread hole short: each shows in the numbers and on the X-ray.

Compared, not validated

Its screws and plates were set beside published bench tests. Some readings agree within the tests' scatter and some do not; each difference is written down with its cause.

30guided cases
12kinds of hardware
6load tests
4bones from open CT scans

Your scans and your data

Built to hold no patient's data.

Only the voxels

Bring a CT as DICOM files, a folder or a zip, or as NIfTI, NRRD or MetaImage. Osteon keeps its voxels and their spacing; names, dates and other tags stay behind.

On your computer

Run on your own machine, Osteon needs no connection: its fonts and pictures come with it, and nothing leaves the computer.

Hosted, by invitation

On a hosted Osteon the owner invites each person, a scan comes in only with your word that it identifies no one, and each account keeps its own bones and record.

Your record is yours

Each act and test is kept as a sentence: read it by day, search it, download it as a spreadsheet, or clear it.

Questions

What people ask first.

What is Osteon?

An educational surgery simulator for fracture fixation. It builds a 3D bone from a CT scan; you break it, reduce it, fix it with plates, screws, nails, wires and frames, and load it to read what your fixation does.

Who is it for?

Medical students heading for orthopedics, residents who want repetitions, and the faculty who teach them.

Is it validated?

No. Each number behind its physics names its source, and its screws and plates were set beside published bench tests, but it has not been validated. It is an educational simulation, not for clinical decision-making.

What do I need to run it?

A recent web browser on a laptop or a desktop. A hosted Osteon needs nothing installed; Osteon can also run on your own computer.

How do I get access?

Osteon is open by invitation, which its owner gives. Book a demo, and ask for one there.

Can I use my own CT scans?

Yes, scans that identify no one: DICOM, NIfTI, NRRD or MetaImage. Osteon keeps their voxels and spacing only, and asks you to confirm that a scan names no patient before it comes in.

What happens to my work?

It is kept as you left it, to open again, even when a connection drops, and you can remove it whenever you like. The privacy page says what is kept, and where.

Book a demo

Thirty minutes, on a real CT.

Screen shared, no slides. Write with a time that suits you, and we will send a link.

Book a demo
  1. 01A bone from a real CTBuilt in 3D in front of you.
  2. 02A guided caseFrom the fracture to the load test.
  3. 03The physicsWhat each number is, and its source.
  4. 04Your own scanIf you bring one that names no one.
  5. 05Your questionsAnd how it would fit your teaching.

See it on a real CT.

Open Osteon on the demo femur, or bring a scan of your own.