Break
Draw the fracture across the bone with the saw, or take the one the scan shows.
Educational simulation · Physics-based
Operate on a bone built from a real CT scan. Break it, fix it with the plates, screws, nails, wires and frames used in the operating room, then load it and read what your fixation does, in newtons and millimeters.
Case 1: lag screw and plate
Lag screw
Take the 4.5 mm partially threaded screw and click the hole. Tighten it to about 80% of its stripping torque.
Its thread past the fracture presses it shut.
Box the bone on two pictures of the scan and it becomes a case. Only its voxels are kept.
Fixed with the hardware of the operating room
What Osteon is
Osteon is a fracture-fixation skills lab on a laptop. It turns a CT scan into a bone you can cut, drill, plate, screw and nail as often as you like. Because it runs real mechanics, it shows what a plastic bone cannot: how hard a lag screw presses the fracture, how near each screw is to stripping, and how far the fracture moves under load.
For medical students heading for orthopedics, residents who want repetitions, and the faculty who teach them.
Readings from Osteon's guided cases
As Osteon's notes record them, on the demo femur. Educational simulation.
How it works
One bone, built from the scan, and the steps of a real operation in their order.
Draw the fracture across the bone with the saw, or take the one the scan shows.
Bring the fragment back with pointed forceps and hold it with K-wires.
Drill, measure and drive the screws, put on the plate, ream and nail, or tie a wire.
Load it along the bone, as the hip in walking, in bending or in torsion, and read what moves.
Guided cases
Each step gives one instruction and its reason, a red ring marks where to work, and the case ends in a debrief with its numbers. There is no score: the numbers are the feedback.
Four topics, each with its progress and the case up next.
Up nextCase 4: weak bone
The step opens its tool and turns the view; you do the work.
Case 1 · Step 2 of 7
Hole for the lag screw
With the 3.2 mm bit, click inside the red ring and drill through the far cortex.
The screw's thread will grip the far fragment.
The strip under the view gives the fracture's state live, in numbers colored by what they mean.
Case 3, a compression plate on the demo femur: the plate at 16% of its yield.
What happened, why, and what to change. Save it as a text file to show a teacher.
The physics
Compression, stripping, plunge and stability come out of the model, so a wrong technique fails for the real reason, and a right one holds.
An open-source medical simulation engine runs the fragments and the hardware under load, and the contact between the broken faces.
Bone strength, thread hold, the steel's limits: each constant names the paper or guide it comes from, or is marked as assumed.
Plunge past the far cortex, strip a screw, lose compression, stop a thread hole short: each shows in the numbers and on the X-ray.
Its screws and plates were set beside published bench tests. Some readings agree within the tests' scatter and some do not; each difference is written down with its cause.
Your scans and your data
Bring a CT as DICOM files, a folder or a zip, or as NIfTI, NRRD or MetaImage. Osteon keeps its voxels and their spacing; names, dates and other tags stay behind.
Run on your own machine, Osteon needs no connection: its fonts and pictures come with it, and nothing leaves the computer.
On a hosted Osteon the owner invites each person, a scan comes in only with your word that it identifies no one, and each account keeps its own bones and record.
Each act and test is kept as a sentence: read it by day, search it, download it as a spreadsheet, or clear it.
Questions
An educational surgery simulator for fracture fixation. It builds a 3D bone from a CT scan; you break it, reduce it, fix it with plates, screws, nails, wires and frames, and load it to read what your fixation does.
Medical students heading for orthopedics, residents who want repetitions, and the faculty who teach them.
No. Each number behind its physics names its source, and its screws and plates were set beside published bench tests, but it has not been validated. It is an educational simulation, not for clinical decision-making.
A recent web browser on a laptop or a desktop. A hosted Osteon needs nothing installed; Osteon can also run on your own computer.
Osteon is open by invitation, which its owner gives. Book a demo, and ask for one there.
Yes, scans that identify no one: DICOM, NIfTI, NRRD or MetaImage. Osteon keeps their voxels and spacing only, and asks you to confirm that a scan names no patient before it comes in.
It is kept as you left it, to open again, even when a connection drops, and you can remove it whenever you like. The privacy page says what is kept, and where.
Book a demo
Screen shared, no slides. Write with a time that suits you, and we will send a link.
Book a demoOpen Osteon on the demo femur, or bring a scan of your own.